Note: When replacing
air cleaner element (5), remove with upper part of air cleaner
housing (4). Insert new air cleaner insert in upper part of air
cleaner housing. Attach upper part of air cleaner housing with air
cleaner element to lower part of air cleaner housing.
Remove
Remove air intake hose (3) from upper part of air cleaner
housing.
For Y 22 XE and Z 22 XE: Unclip tank vent valve (2) from lower
part of air cleaner housing.
Unclip coolant hose (1) from upper part of air cleaner
housing.
Release air cleaner housing from rubber bearings and remove
upwards with air duct hose (6).
|