Check valve stem projection with KM-512. If dimension "I" (17.85 to 18.25 mm) is exceeded, insert new valve and check valve stem projection again. If the valve step projection is still too large despite replacement of the valve, replace the cylinder head. Before installing valve - see operations "Valve, Grind" and "Valve, Grind In". |