F0: DATA LIST - Test Step 23 AUTOM.TRANS. ST. > < Time Allowance

F0:DATA LIST

 

No.

TECH 1 Display

Conditions for Checking

Nominal Value

Trouble Codes

Terminal

22

AUTOMATIC

AT only:

 

42

23/2

 

TRANS.

Ignition ON

OKAY    12V

 

26-pin

 

 

At least 6 s have elapsed since ignition ON

 

 

 

 

 

 

MT always:

DISABLED

 

 

 

 

 

 

 

 

Notes for Trouble-shooting:

Nominal Value:

Cause of Fault:

(If nominal value is not attained)

 

·   Ignition OFF; remove instrument assembly

 

 

·   Release and disconnect 26-pin MID wiring harness plug

 

 

·   Release and disconnect wiring harness plug from AT control unit K85

 

 

·   Ignition ON

 

 

·   Measure voltage to ground in 26-pin MID wiring harness plug Ter. 23:

lower than 1 V

·   Short circuit to + battery voltage in lead between 26-pin MID wiring harness plug Ter. 23 and wiring harness plug for AT control unit K85/Ter. 29

 

·   Measure resistance to ground in 26-pin MID wiring harness plug Ter. 23:

higher than 20 kW

·   Short circuit to ground in lead between 26-pin MID wiring harness plug Ter. 23 and wiring harness plug for AT control unit K85/Ter. 29

 

·   Connect terminal Ter. 29 in wiring harness plug for AT control unit to ground

 

 

·   Measure resistance to ground in 26-pin MID wiring harness plug Ter. 23:

lower than 2 W

·   Interruption in lead between 26-pin MID wiring harness plug Ter. 23 and wiring harness plug for AT control unit K85/Ter. 29

 

Further possible faults

 

·   MID defective

 

 

·   Fault in AT system

 

 

 

 

 

 

 


Related Literature Units
-TABLE 2, TROUBLE CODES - Trouble Code 42 AUTOMATIC TRANS. INFO. CIRCUIT

F0: DATA LIST - Test Step 23 AUTOM.TRANS. ST. > < Time Allowance