Caution

Fuel escapes – observe safety measures and national legislation.

Note:   When draining water, the battery must not be connected or disconnected. No electrical short-circuit may be caused and no electrical connections may be opened. The engine must be turned off for a minimum of 15 minutes to prevent contact between fuel and a hot engine.

  Remove

Hold drain hose (1) in suitable container. Vent bolt (2) and drain bolt (3) – open 1 turn. Drain fluid until pure fuel escapes.

  Install

Close vent and drain screw. Put drain hose (1) on frame side member.