No.
|
TECH 1 Display
|
Conditions for
Checking
|
Nominal Value
|
Trouble Codes
|
Terminal
|
|
04
|
DRIVER DOOR SW.
|
Ignition ON
Driver's door CLOSED
Driver's door OPEN
|
OPEN 12V
CLOSED 0V
|
-
|
7
8-pin
plug
|
|
|
|
Note:
The TECH 1 display indicates the switch condition of
the driver's door contact switch.
DRIVER DOOR
SW.CLOSED means:
Switch closed = 0 volts, door open
|
|
|
|
|
|
|
|
|
|
|
|
Notes on Trouble-shooting:
|
Nominal Value:
|
Cause of fault:
(If nominal value is not
attained)
|
If nominal value OPEN
12V is not attained:
|
|
|
|
· Remove driver's door contact switch
· Using multimeter, measure voltage at
driver's door contact switch/ lead GR (grey) to ground
|
higher than 11 V
|
· Lead interruption between driver's door
contact switch and Ter. 30
|
|
If nominal value is attained:
|
|
· Lead interruption between driver's door
contact switch S47 and control unit K103/ Ter. 7
|
|
If nominal value CLOSED 0V is not attained:
|
|
|
|
· Check whether actuating bolt of
driver's door contact switch jams
|
Actuating pin can be moved
|
· Driver's door contact switch faulty
|
|
· Disconnect battery negative terminal
· Remove driver's door contact switch S47
· Using multimeter, measure resistance at
two lead connections to switch housing
Actuating
pin not pressed:
Actuating
pin pressed in:
|
higher than 200 kW
approx. 0 W
|
· Driver's door contact switch S47
defective
|
|
Further possible faults:
|
|
· Ground transfer resistance between S47
and body too high
· Control unit K103 defective
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|