Measure
Measure tensioning of the planetary gear set P2 with hex socket wrench (1) size 36 and MKM-536-A (2). Clamp assembly with KM-696 in vice. Secure with upper fixing bolt (3) against turning. Allow fixing bolt (3) to rest with the thread at the sides of the recess (arrow); do not lock against the planetary gears by tightening (in which case the component is no longer turnable). Carry out several measurements and take average value.
Starting torque: 0.55 to 1.35 Nm / 0.4 to 0.9 lbf. ft.