B-10, Functional check of pinch guard |
Test |
Work order description |
Nominal value |
T01 |
Functional check |
|
|
• The pinch guard is effective within the range at which a cylindrical body (e.g. a plastic pipe) with a diameter of 4 mm fits into the diameter of the window opening (also into the diagonal at the A-pillar). |
Function of pinch guard O.K. |
|
If, on commencement of the closing process, the diameter of the window opening is between 4 mm and 200 mm, the window is automatically opened up to the position from which the closing process started, but at least by approx. 40 mm, if the window encounters an object. |
|
|
If, on commencement of the closing process, the diameter of the window opening is greater than 200 mm, the window is automatically opened up to the position at which the diameter of the window opening is 200 mm, but at least by approx. 40 mm, if the window encounters an object. |
|
|
The pinch guard cannot be switched off. |
|
|
Yes: E01 |
No: E02 |
B-10, Functional check of pinch guard |
Result |
Cause of fault |
E01 |
• No fault determinable |
E02 |
• Programme corresponding window winder |
|
or |
|
• Replace corresponding window winder motor, if not programmable |
B-11, Functional check, closing window via central door locking
|