volkswagen Workshop Repair Guides

Volkswagen Workshop Service and Repair Manuals

With Manufacturer's Scan Tool|Page 4185 > < With Manufacturer's Scan Tool
Page 2
background image

-

Measure resistance between -N239- terminals.
Specification: 25 to 45 Ohms

If specification not obtained

-

Replace Intake Manifold Change-over Valve -N239-.

If specification obtained

-

Switch Fluke 83 multimeter to 20 Volt range.

-

Connect multimeter between terminals 1 and 2 of ECM connector using jumper wires from VW 1594 Adapter kit.

-

Start engine and let idle.
-

Specification: between 5 and 6 Volts

-

Switch OFF ignition.
-

Voltage value must rise to 11 to 15 Volts (battery Voltage) and after approx. 3 seconds fall to 0 Volts.

If Voltage values do not change as described

With Manufacturer's Scan Tool|Page 4185 > < With Manufacturer's Scan Tool