volkswagen Workshop Repair Guides

Volkswagen Workshop Service and Repair Manuals

Heated Oxygen Sensor (HO2S) -G39- Before Converter, Checking|Page 1268 > < Heated Oxygen Sensor (HO2S) -G39- Before Converter, Checking|Page 1266
Page 2
background image

Read Measuring Value Block
Input display group number XXX

-

Press keys 0, 3 and 0 for "Display group number 30" and confirm entry with Q key.

Indicated on display: (1 to 4 = Display zones)

Read Measuring Value Block 30

->

1

2

3

4

-

Check the operating condition of the Oxygen sensor control after catalytic converter (display zone 2):
Specification: 111

NOTE:  The bits in display zone 2 will not be set to 1 until the catalytic converter temperature has risen to above 352 degree C ( display group 34,
display zone 2).

Significance of 3 digit number block in display zone 2:

Change to display group 37 as follows:

-

Press C key.

-

Press keys 0, 3 and 7 for "Display group number 37" and confirm entry with Q key.

Indicated on display: (1 to 4 = Display zones)

Read Measuring Value Block 37

->

1

2

3

4

-

Check dwell period of Oxygen sensor control before catalytic converter in display zone 3:
Specification: 0 to 200 ms

-

Check result of diagnosis in display zone 4:
Specification: B1-P2 OK

NOTE:  The Oxygen sensor control after catalytic converter is master of the Oxygen sensor control before catalytic converter and serves as a corrective
regulation.

It corrects slight movements of the mixture (e.g. towards rich) by the Oxygen sensor before catalytic converter in that it holds the Oxygen sensor control
at the upper or lower point for a certain period (dwell period). If the period is in the positive range (e.g. 50 ms), the mixture is moved towards rich. If the
period is in the negative range (e.g. -50 ms) the mixture is moved towards lean.

-

Check Oxygen sensor voltage in display zone 2:
Specification: 0 to 1 V (can fluctuate slightly)

Heated Oxygen Sensor (HO2S) -G39- Before Converter, Checking|Page 1268 > < Heated Oxygen Sensor (HO2S) -G39- Before Converter, Checking|Page 1266