volkswagen Workshop Repair Guides

Volkswagen Workshop Service and Repair Manuals

Symptom Related Diagnostic Procedures|Page 6086 > < Symptom Related Diagnostic Procedures|Page 6084
Page 2
background image

- Use hydrometer to extract excessive electrolyte until fluid level is same as inner plastic peg level marking if the electrolyte level is too high.

- If electrolyte level is too low, fill up to max. marking with distilled water using battery filling bottle VAS 5045 or equivalent.

CAUTION! DO NOT overfill. Overfilled batteries can boil over. Too little electrolyte reduces the service life of the battery.

Notes:

- The construction of the filler support on filling bottle VAS 5045 prevents an overfilling of the battery cells and therefore stops electrolyte from
leaking out When the max. level is reached, the flow of distilled water into the battery cells is interrupted.

- Use distilled water only. This prevents contamination of the battery electrolyte and the associated increased self discharge.

- Reinstall battery cells sealing plug again if necessary.

It is absolutely necessary to use original sealing plugs in the battery screwed openings to guarantee the battery is sealed correctly.

Use onginal sealing plugs of same construction if lost or damaged.

The sealing plugs must be installed with an 0-ring.

Load Testing

Load test

The electrolyte specific gravity test in conjunction with the battery load test provides specific information of the battery condition.

Special tools and equipment

Battery tester VAS 1979, VAS 5033, Christie Automotive BT-9000 or equivalent.

Symptom Related Diagnostic Procedures|Page 6086 > < Symptom Related Diagnostic Procedures|Page 6084