Connect VAG1390 hand vacuum pump at vacuum hose (arrow) to combination valve.

Note:

-

Do not use pressurized air for the following test!

-

Remove intake hose to Secondary Air Injection (AIR) pump motor at upper air filter housing (arrow) and blow into it with light pressure. 
Combination valve must close.

-

Operate vacuum pump. Combination valve must open.

If combination valve does not open:

-

Replace Combination valve.