volkswagen Workshop Repair Guides

Volkswagen Workshop Service and Repair Manuals

Leak Detection Pump, Evaporative System|Diagrams|Page 2504 > < Leak Detection Pump, Evaporative System|Diagrams|Page 2502
Page 2
background image

-

Remove 3-pin connector -1- for Leak Detection Pump (LDP) -V144-.

-

Connect Multimeter (Fluke 83 or equivalent) between terminals 1 and 3 of Leak Detection Pump (LDP) for resistance measurement.
Specification: 640 to 720 Ohms.

-

Connect Multimeter (Fluke 83 or equivalent) between terminals 2 and 3 of Leak Detection Pump (LDP) for resistance measurement.
Specification: 14 to 18 Ohms.

If specified values are not obtained:

-

Replace Leak Detection Pump (LDP) -V144-

Checking voltage supply

Test requirement

-

All fuses must be OK.

Test sequence

Leak Detection Pump, Evaporative System|Diagrams|Page 2504 > < Leak Detection Pump, Evaporative System|Diagrams|Page 2502