A/T Shift Indicator Module: Testing and Inspection
Selector Lever Sensor System Control Module Voltage Supply, Checking

Selector Lever Sensor System Control Module Voltage Supply, Checking

Special tools, testers and auxiliary items required

-

Multimeter.

-

Wiring diagram.

Test requirements

-

Fuse SC6 OK.

-

Fuse SC18 OK.

-

Battery voltage at least 12.5 volts.

-

All electrical consumers such as, lights and rear window defroster, switched off.

-

Selector lever in "P".

-

A/C switched off.

-

Ground (GND) connections between engine/transmission/chassis OK.

-

Ignition switched off.

Test procedure

-

Perform a preliminary check to verify the customers complaint.  See: Powertrain Management/Computers and Control Systems/Testing and
Inspection/Scan Tool Testing and Procedures/Preliminary Check

Start diagnosis

-

Disconnect the Selector Lever Sensor System Control Module J587 electrical harness connector.

Checking voltage

-

Using a Multimeter, check the Selector Lever Sensor System Control Module J587 electrical harness connector terminal 10 to Ground (GND) for
voltage.

-

Switch the ignition off.

Specified value: battery voltage.

If the specified value was not obtained:

-

Check the Selector Lever Sensor System Control Module J587 electrical harness connector terminal 10 to the Battery A the for an open circuit or
short to Ground (GND).

-

Check the wiring connection for damage, corrosion, lose or broken terminals.

-

If necessary, repair the faulty wiring connection.

If the specified value was obtained:

-

Using a Multimeter, check the Selector Lever Sensor System Control Module J587 electrical harness connector terminal 9 to Ground (GND) for
voltage.

Specified value: battery voltage.

If the specified value was not obtained:

-

Check the Selector Lever Sensor System Control Module J587 electrical harness connector terminal 9 to the Generator (GEN) C terminal L for an
open circuit or short to Ground (GND).

-

Check the wiring connection for damage, corrosion, lose or broken terminals.

-

If necessary, repair the faulty wiring connection.

If the wiring and voltage were OK:

-

Using a Multimeter, check the Selector Lever Sensor System Control Module J587 electrical harness connector terminal 5 to Ground (GND) for
voltage.

Specified value: battery voltage.

If the specified value was not obtained:

-

Check the Selector Lever Sensor System Control Module J587 electrical harness connector terminal 5 to the Generator (GEN) C terminal L for an
open circuit or short to Ground (GND).

-

Check the wiring connection for damage, corrosion, lose or broken terminals.

-

If necessary, repair the faulty wiring connection.

If the wiring and voltage were OK:

Selector Lever Sensor System Control Module Voltage Supply, Checking|Page 79 > < A/C - Does Not Get Cold Enough|Page 73