| Push all seals -A- over contact pins slightly. |
–
| Without canting it, place control unit onto hydraulic unit. |
The seals are thus moved to end position. |
–
| Bolt hydraulic unit and control unit with enclosed, new Torx bolts. |
Note t
| A new control unit may be mounted on an existing hydraulic unit max. twice to guarantee impermeability of the elastic seal. |
t
| A control unit which has already been operated in a vehicle must not be installed a second time. |
|
|
|