Golf GL L4-2.0L (AZG) (2001)
and Control Systems/Testing and Inspection/Scan Tool Testing and Procedures/With Generic Scan Tool/Diagnostic Mode 4: Reset/Erase
Diagnostic Data
-
Generate readiness code. See: Powertrain Management/Computers and Control Systems/Testing and Inspection/Monitors, Trips, Drive Cycles
and Readiness Codes
If indication remains at approx. 140.0 degree C:
-
End diagnosis and switch ignition off.
-
Check wires according to wiring diagram.
Checking wiring
-
Connect test box to control module wiring harness, connect test box for wiring test. See: Powertrain Management/Computers and Control
Systems/Testing and Inspection/Reading and Clearing Diagnostic Trouble Codes/Scan Tool Connecting/With Generic Scan Tool/Test Box,
Connecting For Wiring Test
-
Check wires between test box and 4-pin connector for open circuit according to wiring diagram.
Terminal 3 + socket 93
Terminal 4 + socket 108
Wire resistance: max: 1.5 Ohms
-
Also check wires for short circuit to each other, to vehicle Ground (GND) and to B+. Specified value: Infinite Ohms
If no malfunctions are found in wires:
-
Measure resistance at Engine Coolant Temperature (ECT) sensor -G62-, terminals C (signal) and D (Ground -GND-).