volkswagen Workshop Repair Guides

Volkswagen Workshop Service and Repair Manuals

Procedures|Page 12079 > < Procedures|Page 12077
Page 11
background image

‹› High pressure refrigerant may leak out if refrigerant circuit is not discharged.

‹› Always evacuate refrigerant prior to opening refrigerant circuit.

-

From the engine compartment, remove bolts - 1 - (12 Nm) for refrigerant lines - 2 -.

-

Disconnect refrigerant lines from expansion valve - 3 -. 

CAUTION!
‹› Always plug open refrigerant line connections to prevent dirt and moisture contamination.

‹› Where applicable, use sealing caps from replacement expansion valve. 

-

Cover floor carpet in vehicle interior with leak-proof foil and absorbent paper.

‹› Observe screw position, length and orientation during removal.

Procedures|Page 12079 > < Procedures|Page 12077