Jetta Sedan L5-2.5L (BGP) (2005)
‹› High pressure refrigerant may leak out if refrigerant circuit is not discharged.
‹› Always evacuate refrigerant prior to opening refrigerant circuit.
-
From the engine compartment, remove bolts - 1 - (12 Nm) for refrigerant lines - 2 -.
-
Disconnect refrigerant lines from expansion valve - 3 -.
CAUTION!
‹› Always plug open refrigerant line connections to prevent dirt and moisture contamination.
‹› Where applicable, use sealing caps from replacement expansion valve.
-
Cover floor carpet in vehicle interior with leak-proof foil and absorbent paper.
‹› Observe screw position, length and orientation during removal.