Notes:
-
◆ If something different is indicated on display =>fault reader operating instructions
-
◆ If an incorrect input causes "Fault in the data transfer!" to be indicated, disconnect cable from fault reader, then reconnect and repeat work steps.
-
‒ Slowly open throttle valve fully and observe the numerical figures in display zones 2 and 3.
- Display zone 2:
The numerical figure must increase uniformly until throttle
valve is 1/4 open and then remain constant
- Display zone 3:
The numerical figure must increase uniformly over the entire
range
-
‒ Press ⇒ key.
-
‒ Input 06 for "End output" and confirm with Q.
If the specifications are not attained:
-
‒ Carry out electrical check, Test step 16
=> Page 01-20
, if necessary renew injection unit lower part.