volkswagen Workshop Repair Guides

Volkswagen Workshop Service and Repair Manuals

Ambient Temperature Sensor / Switch HVAC|Testing and Inspection|Page 707 > < Ambient Temperature Sensor / Switch HVAC|Testing and Inspection
Page 2
background image

If the specified values were Not obtained:

-

Replace the Ambient Air Temperature Sensor (G17). Refer to the Repair Information.

If the specified values are obtained, continue the test according to the following table:

Checking wiring

-

Turn the ignition switch ON.

-

Connect a multimeter to terminals 1 and 2 of the Ambient Air Temperature Sensor (G17) electrical harness connector. 

Specified value: near 5.02 V

-

Turn the ignition switch OFF.

If the specified value was Not obtained:

-

Remove the Instrument Cluster. Refer to the Repair Information.

-

Disconnect the Instrument Cluster harness.

-

Using a multimeter, check the Ambient Air Temperature Sensor (G17) electrical harness connector to the Instrument Cluster electrical harness T32
connector for an open circuit or a short, refer to the wiring diagram.

Specified value: 1.5 ohms max.

If the specified value was Not obtained:

-

Check the wiring for an open, high resistance or short circuit to voltage or ground.

-

Check the electrical harness connector for damage, corrosion, loose or broken terminals.

-

If necessary, repair the faulty wiring connection.

If the specified value was obtained:

Replace the Instrument Cluster. Refer to the Repair Information.