Servicing unit injector > < Fitting locations overview
Repairing intake manifold flap
Repairing intake manifold flap
The intake manifold flap is closed for approx. 3 seconds when stopping engine and then opens again. This reduces the stop jolt.
Check intake manifold flap change-over → Chapter
   
1 - Intake manifold
2 - O-ring
q   Renew
3 - Exhaust gas recirculation valve
4 - Intake connecting pipe
q   With exhaust gas recirculation valve and intake manifold flap.
5 - 10 Nm
6 - From charge air cooler
7 - Seal
q   Renew
8 - Connecting pipe
q   To exhaust manifold
9 - 25 Nm
10 - 10 Nm
11 - Bracket
12 - Vacuum actuator
13 - Variable intake manifold flap change-over valve
q   Checking → Chapter
14 - Vacuum supply
q   From vacuum pump

   