Control motor for natural air valve and recirculation valveV154 (version 1) - remove and install|Installation > < Control motor for natural air valve and recirculation valveV154 (version 1) - remove and install
Removal
Removal
–  Remove the Natural air fan -V2- → Chapter.
–  Carefully cut the cable fastenings.
–  Disengage the connector.
–  Remove the fastening screws -arrows-.
–  Press the locks -1- and remove the support with the Control motor for the fresh air valve and recirculation valve -V154-.
   

   
–  Press support locks outwards -arrows- and remove the Control motor for natural air valve and recirculation valve -V154- from support.
  S87-0116