t
| Loosen and tighten bolts and securing nuts for covers and housings
diagonally. |
t
| Torque settings are specified for unoiled bolts and nuts. |
t
| Threads of bolts secured with locking fluid must be cleaned
with a wire brush. Then insert bolts with locking fluid AMV 185 100
A1. |
t
| Use a thread chaser to clear residual locking fluid from all
threaded holes into which self-locking bolts are to be screwed. Otherwise
there is a danger of bolts shearing when subsequently being removed. |
t
| Always renew self-locking bolts and nuts. |
|
|
|