volkswagen Workshop Repair Guides

Volkswagen Workshop Service and Repair Manuals

Variable Induction Control Valve|Testing and Inspection|Page 2870 > < Variable Induction Control Actuator|Testing and Inspection|Page 2866
Page 1
background image

Variable Induction Control Valve: Testing and Inspection

Intake Manifold Tuning Valve N156, Checking

Special tools, testers and auxiliary items required

-

Multimeter.

-

Wiring diagram.

Test requirements

-

Fuse SB38 OK.

-

The Power Supply Relay (terminal 30, B+) J317 OK.

-

The parking brake engaged.

-

The battery voltage at least 12.5 V.

-

The selector lever of automatic transmission in position "P" or "N".

-

All electrical consumers switched off (radiator fan must NOT run during test).

-

A/C switched off.

-

The fuel tank at least 1/4 filled.

-

The ignition switched off.

Test procedure

-

Perform a preliminary check to verify the customers complaint.  See: Computers and Control Systems/Testing and Inspection/Scan Tool Testing
and Procedures/Preliminary Check

Start diagnosis

-

Disconnect the Intake Manifold Tuning (IMT) Valve N156 electrical harness connector.

Checking internal resistance

-

Using a Multimeter, check the Intake Manifold Tuning (IMT) Valve N156 terminals 1 to 2 for resistance

Specified value: 450 to 1000 ohms.

If the specified value was not obtained:

-

Replace the Intake Manifold Tuning (IMT) Valve N156.

If the specified value was obtained:

Checking voltage

Crank the engine.

Variable Induction Control Valve|Testing and Inspection|Page 2870 > < Variable Induction Control Actuator|Testing and Inspection|Page 2866