volkswagen Workshop Repair Guides

Volkswagen Workshop Service and Repair Manuals

Rearview Camera Control Module (J772), Coding|Page 6130 > < Rearview Camera Control Module (J772), Coding
Page 1
background image

Rear Vision Camera: Testing and Inspection
Rearview Camera System, Calibrating

Rearview Camera System, Calibrating

=> [ Preliminary Work for Calibration ] 

=> [ Rearview Camera System, Calibrating ] 

Special tools, testers and auxiliary items required

‹› Vehicle Diagnosis, Testing and Information System ( VAS 5051A)

‹› Calibration tool for lane changing assist (VAS 6350 )

After performing service work on the vehicle, it may be necessary to calibrate the rear view camera system anew. In detail, this is the case after:

‹› Removing and installing rear view camera

‹› Replacing the rearview camera system control module

‹› Repair work performed on rear lid following an accident

‹› An axle alignment

‹› Performing a repair at front or rear axle

Extensive preparatory work must be completed before the appropriate calibrating procedure can be performed using the (VAS 5051A) or Vehicle
Diagnosis And Service Information System ( VAS 5052). This is described in the following.

Preliminary Work for Calibration

Vehicle must stand on a firm and level surface to perform the calibration. No persons may be in the vehicle interior during the measurement. Vehicle
must not be moved during the measurement, opening and closing of vehicle doors is to be avoided.

-

Connect the (VAS 5051A). Refer to=> [ Vehicle Diagnosis, Testing and Information Systems ] See: Power and Ground Distribution/Wiring
Harness/Service and Repair/Procedures/Vehicle Diagnosis, Testing and Information Systems.

-

Bring the Steering Angle Sensor (G85) into 0 - position (wheels straight ahead).

Overview Of The Assembled Measuring Device:

Rearview Camera Control Module (J772), Coding|Page 6130 > < Rearview Camera Control Module (J772), Coding