If this is not the case, paddles must be corrected accordingly via clamping screws on the wheel pick-ups.

-

Hold the distance laser for distance measurement firmly by the hand in the angle bracket on the measuring device while the laser beam can be seen
on the paddle. Now press the ON button briefly for the distance measurement. When doing this, the following display appears on screen:

The distance measurement is specified on the display in meters.

-

Note the value read off.

-

Repeat measuring procedure in the same manner for the other rear wheel on the other side of the calibration device.

The distance value must be the same on both sides. If the value is not identical, align the calibration device only as long until the values on both sides
are identical.

When aligning the calibration device, make sure the distance laser beam still strikes the center above the VW logo and indicator of fluid-level remains
centered. If necessary, make further corrections accordingly.

The dimension for distance that was measured must be entered during calibration into the (VAS 5051A) or Diagnostic Operation System (VAS 5052)
in millimeters.

Rear view camera system, calibrating, refer to => [ Rearview Camera System, Calibrating ].

Rearview Camera System, Calibrating

‹› Observe the points regarding the preparation for calibrating. Refer to => [ Preliminary Work for Calibration ].

-

Connect the (VAS 5051A). Refer to => [ Vehicle Diagnosis, Testing and Information Systems ] See: Power and Ground Distribution/Wiring
Harness/Service and Repair/Procedures/Vehicle Diagnosis, Testing and Information Systems.