volkswagen Workshop Repair Guides

Volkswagen Workshop Service and Repair Manuals

Refrigerant circuit with expansion valve > < Evaporator output temperature senderG263 or evaporator temperature sensorG308
Pressures and temperatures in the refrigerant circuit
Pressures and temperatures in the refrigerant circuit
  WARNING
When working on the refrigerant circuit, observe generally applicable safety rules and the pressurised container regulations.
The pressures and temperatures in the refrigerant circuit depend on the momentary operating conditions (e.g. engine speed, speed 1, 2, or 3 of radiator fan, engine temperature, whether air conditioner compressor is on or off) as well as environmental influences (e.g. ambient temperature, humidity, required cooling output).
In vehicles with air conditioner compressor regulating valve -N280-, the pressure on the low-pressure side is varied by activating the valve.
Therefore, the values given in the following table may only be considered guidelines. They occur at an engine speed of 1500 to 2000 rpm and an ambient temperature of 20° C after about 20 minutes.
The locations of connections provided for pressure measurements can be found in the vehicle-specific coolant circuits.
→ Rep. gr.87
At 20 °C and with the engine stopped, the refrigerant circuit will adjust itself to a pressure of 4.7 bar positive pressure → Chapter.
   

Refrigerant circuit with expansion valve > < Evaporator output temperature senderG263 or evaporator temperature sensorG308