| Set battery to respective battery type with INFO. |
In the display, the symbol -1- for „Service charge for wet batteries“ or symbol -2- for „Service charge for gel/absorbent glass mat batteries“ will appear. |
–
| Set battery capacity (Ah) of battery for charging using respective button „Up“↑ or „Down“↓. |
–
| Connect red terminal clamp „+“ to positive terminal on battery. |
Note In vehicles with start/stop function and battery monitor control unit -J367- fitted, black terminal clamp „-“ must be connected to body earth. Connecting it to battery negative terminal will cause start/stop system to malfunction. |
–
| Connect black terminal clamp „-“ to negative terminal. |
The charger unit recognises the voltage required for the connected battery (6 V, 12 V or 24 V) and initiates the charging sequence. |
|
|
|