240 L4-2127cc 2.1L SOHC Turbo B21FT FI (1982)
H8 Example:
Locked starter motor
I = Ix . U / Ux
Measured values: Ix = 350 A
Ux = 5 V
Manufacturer's specifications:
I = 410 - 490 A
U = 6.5V
Calculate I, and compare it to the manufacturer's specifications (I).
I = Ix . U / Ux
I = 350 x 6.5 / 5
I = 2275 / 5
I = 455 A
The calculated value of 455 A lies within the manufacturer's specifications (i.e. 410-490 A).
The measured value 350 A has been converted to 455 A and is thereby a fully acceptable result.