-Ignition off.

-Ignition coil disconnected

Connect an ohmmeter between ignition coil terminals -1 and 15+.

The ohmmeter should read approx. 2 OHMS.

If the value is OK

Intermittent fault.

-Check the wiring between power stage terminal 1 and ignition coil terminal -1 for intermittent grounding.

If this value Is Incorrect

-Try using a new ignition coil.