Wastegate Actuator: Adjustments
Wastegate Valve, Adjusting

Wastegate valve, adjusting

Special tools:

999 5544 REGULATOR  See: Tools and Equipment/999 5544 Regulator 
999 5646 Pressure gauge  See: Tools and Equipment/999 5646 Pressure Gauge 

Manometer

Use test equipment 999 5646 Pressure gauge  See: Tools and Equipment/999 5646 Pressure Gauge  to measure the adjustment pressure.
The manometer must always hang vertically when taking readings. This is to ensure that the values obtained are correct.

Removing the heat deflector plate

Pressure Regulator, Checking/Adjusting|Page 6151 > < Pressure Regulator, Checking/Adjusting|Page 6149