V90 L6-2.9L VIN 96 B6304S (1998)
Checking Resistance Of Solenoids S1, S2 And SL
-
Connect ohmmeter between solenoid S1 connector pin and ground terminal on transmission. Instrument should indicate 10 - 15 ohm.
-
Repeat measurement for solenoids S2 and SL. Instrument should indicate 10 - 15 ohm.
-
Solenoid in question must be replaced if instrument indicates different value in any of above measurements.
Check Resistance Of Solenoid STH
-
Connect ohmmeter between two pins in solenoid connector. Instrument should indicate 2 - 6 ohm.
-
Solenoid must be replaced if instrument indicates different value.
Replacement Of Solenoids
Removing solenoids S1 and S2
-
Remove solenoid retainer.
-
Withdraw solenoids S1 and S2 from control system.