Install the filler plug (Torx 55). Use a new O-ring. Moisten the new O-ring using transmission fluid and tighten.

Installing the air cleaner (ACL)

Install the air cleaner (ACL) housing.  See: Filters/Air Cleaner Housing/Service and Repair 

Checking the oil level

Connect the diagnostic equipment and read the transmission fluid temperature continuously.
Start the engine.

Note! Leave the engine running during the entire check.

Note! The following measure must be carried out quickly to avoid overheating the fluid.

Run through all the positions between P and D on the gear selector. Stop at each position for at least 2 seconds. Perform this process twice.

Allow the transmission fluid to heat up to 50 °C.

Note! The fluid will not heat up faster by stalling.

Place a lower drip shield on the floor under the vehicle.
While the engine is running, remove the integrated level plug (Torx 40).
Allow the excess fluid to run out.
When the fluid is between 50 °C and 60 °C, check that the transmission fluid has stopped running out and is only dropping from the level plug hole.

Caution! It is essential the temperature not exceed 60 °C, as this can result in the transmission fluid level being too low.