CL L4-2156cc 2.2L SOHC F22B1 MFI (1997)
4. If the clearance exceeds the service limit, measure the thicknesses of 2nd gear and the spacer.
-
2ND GEAR
-
Standard: 28.92 - 28.97 mm (1.139 - 1.141 inch)
-
SPACER
-
Standard: 29.07 - 29.09 mm (1.1445 - 1.1453 inch)
-
If the thicknesses of 2nd gear and the spacer are less than the standard, replace them with new ones.
-
If the thicknesses of 2nd gear and the spacer are within the standard, replace the 1st/2nd synchro hub with a new one.