acura Workshop Repair Guides

Acura (Honda) Workshop Service and Repair Manuals

Connecting Rod Bearing Inspection|Page 2395 > < Connecting Rod Bearing Inspection|Page 2393
Page 2
background image

-

The difference between measurements on each journal must not be more than the service limit.

Journal Taper:

Standard (New): 0.005 mm (0.0002 inch)maximum
Service Limit: 0.010 mm (0.0004 inch)
 

Connecting Rod Bearing Inspection|Page 2395 > < Connecting Rod Bearing Inspection|Page 2393