acura Workshop Repair Guides

Acura (Honda) Workshop Service and Repair Manuals

Radiator and Condenser Fans High Speed Circuit|Page 3807 > < Radiator and Condenser Fans High Speed Circuit|Page 3805
Page 3
background image

NO - Repair open in the wire between the condenser fan relay and the A/C diode A..

14. Disconnect the jumper wire.
15. Reinstall the condenser fan relay.
16. Disconnect the condenser fan 2P connector.
17. Turn the ignition switch ON (II), then turn the A/C and fan switches ON.

18. Measure the voltage between the No.2 terminal of the condenser fan 2P connector and body ground.

Is there battery voltage?

YES - Go to step 19.

NO - Repair open in the wire between the condenser fan relay and the condenser fan.

19. Turn the A/C and fan switches OFF, then turn the ignition switch OFF.
20. Reconnect the condenser fan 2P connector.

21. Connect the No.1 terminal of the condenser fan 2P connector to body ground with jumper wire.
22. Turn the ignition switch ON (II), then turn the A/C and fan switches ON.

Does the condenser fan run?

YES - Go to step 23.

NO - Replace the condenser fan motor.

23. Turn the A/C and fan switches OFF, then turn the ignition switch OFF.
24. Disconnect the jumper wire.
25. Remove the fan control relay from the multi-relay box, and test it.

Is the relay OK?

YES - Go to step 26.

NO - Replace the fan control relay.

26. Turn the ignition switch ON (II), then turn the A/C and fan switches ON.