CL TYPE S V6-3.2L SOHC (2001)
Air Door Actuator / Motor: Testing and Inspection
Recirculation Control Motor
Recirculation Control Motor Test
1. Disconnect the 5P connector from the recirculation control motor.
NOTE: Incorrectly applying power and ground to the recirculation control motor will damage it. Follow the instructions carefully.
2. Connect battery power to the No. 5 terminal of the recirculation control motor, and ground the No. 1 and No. 2 terminals; the recirculation control
motor should run smoothly. To avoid damaging the recirculation control motor, do not reverse power and ground. Disconnect the No.1 or No.2
terminals from ground; the recirculation control motor should stop at Fresh or Recirculate. Don't cycle the recirculation control motor for a long
time.
3. If the recirculation control motor does not run in step 2, remove it, then check the recirculation control linkage and doors for smooth movement.
-
If the linkage and doors move smoothly, replace the recirculation control motor.
-
If the linkage or doors stick or bind, repair them as needed.