acura Workshop Repair Guides

Acura (Honda) Workshop Service and Repair Manuals

Air Mix Control Motor|Page 10102 > < Air Mix Control Motor|Page 10100
Page 1
background image

Air Door Actuator / Motor: Testing and Inspection
Recirculation Control Motor Circuit Troubleshooting

Recirculation Control Motor Circuit Troubleshooting

1. Check the No. 3 (7.5 A) fuse in the driver's under-dash fuse/relay box.

Is the fuse OK?

YES - Go to step 2.

NO - Replace the fuse, and recheck. 

2. Disconnect the recirculation control motor 5P connector.
3. Turn the ignition switch ON (II).

4. Measure the voltage between the No. 5 terminal of the recirculation control motor 5P connector and body ground.

Is there battery voltage? 

YES - Go to step 5.

NO - Repair open in the wire between the No. 3 fuse in the driver's under-dash fuse/relay box and the recirculation control motor.

5. Turn the ignition switch OFF.
6. Test the recirculation control motor.

Is the recirculation control motor OK ? 

YES - Go to step 7. 

NO - Go to step 12.

7. Disconnect climate control unit connector B (20P).

8. Check for continuity between the No. 9 and No. 10 terminals of climate control unit connector B (20P) and body ground individually.

Is there continuity?

YES - Repair short to body ground in the wire(s) between the climate control unit and the recirculation control motor. 

NO - Go to step 9.

Air Mix Control Motor|Page 10102 > < Air Mix Control Motor|Page 10100