High Pressure Safety Valve HVAC: Service and Repair

Compressor Relief Valve Replacement

1. Recover the refrigerant with a recovery/recycling/charging station.

2. Remove the relief valve (A) and the O-ring (B). Plug the opening to keep foreign matter from entering the system and the compressor oil from

running out.

3. Clean the mating surfaces.
4. Replace the O-ring with a new one at the relief valve, and apply a thin coat of refrigerant oil before installing it.
5. Remove the plug, and install and tighten the relief valve.
6. Charge the system.