Control Assembly: Testing and Inspection
Recirculation Control Motor

Recirculation Control Motor

1. 

Connect the battery positive to the 3 terminal of the recirculation control motor connector and negative to 2 terminal.
2.  Using a jumper wire connect the 2 terminal and 1 or 4 terminal.

-

On the recirculation door REC position, the motor should turn with the 2 terminal connected to 1 terminal.

^  On the door FRESH position, the motor should turn with the 2 terminal connected to 4 terminal.

4.  The motor automatically stops after half turn with the jumper wire connected.