Control Assembly: Testing and Inspection
Function Control Motor

Function Control Motor

1.  Connect the battery positive terminal to the 5 terminal of the function control motor and negative to the 1 terminal.
2.  Using jumper wire short the 1 terminal individually to the 2, 3, 4, 7 and 8 terminals to follow the order.

^  The motor should run each time the short circuit is made.