Integra L4-1678cc 1.7L DOHC (VTEC) FI (1992)
8. If distance (B) is less than the standard, replace the spacer collar with a new one.
If distance (B) is within the standard, measure the thickness of 5th gear.
Standard: 31.42-31.47 mm (1.237-1.239 in)
Service Limit: 31.3 mm (1.232 in)
-
If the thickness of 5th gear is less than the service limit, replace 5th gear with a new one.
-
If the thickness of 5th gear is within the service limit, replace the 5th~reverse synchro hub with a new one.