Integra L4-1797cc 1.8L DOHC (VTEC) (1996)
Torque Converter Clutch Solenoid: Service and Repair
1. Remove the mounting bolts and lock-up control solenoid valve A/B assembly.
2. Check the lock-up control solenoid valve fluid passages for dust or dirt, and replace as an assembly, if necessary.
3. Clean the mounting surface and fluid passages of the lock-up control solenoid valve assembly, and install a new lock-up control solenoid valve
A/B with a new filter/gasket.
4. Check the connector for rust, dirt or oil, and reconnect it securely.