Air Door Actuator / Motor: Service and Repair

Recirculation Control Motor / Replacement

1. Disconnect the 4P connector from the recirculation control motor, and remove the wire harness clip from it.

2. Remove the two screws, the recirculation control motor and the flange collar.
3. Install in the reverse order of removal.

After installation, make sure the recirculation control motor runs smoothly.