acura Workshop Repair Guides

Acura (Honda) Workshop Service and Repair Manuals

Voltage Regulator|Testing and Inspection|Page 4875 > < All Technical Service Bulletins for Alternator Pulley:|89018
Page 1
background image

Voltage Regulator: Testing and Inspection

1.

Ensure battery is fully charged and that alternator belt, connections at alternator and main fuses are in satisfactory condition.

2.

Ensure that fuse No. 9 in the dash fuse panel and fuse No. 38 in underhood relay box are in satisfactory condition.

3.

Disconnect electrical connector from alternator.

Fig. 9 Alternator test connections. 1988 Legend

4.

Turn ignition switch on and ensure battery voltage exists between alternator connector black/yellow wire terminal and ground, and between
yellow/blue wire terminal and ground, Fig. 9. If no voltage exists, check for blown fuse No. 9 or open in black/yellow or yellow/blue wires.

Voltage Regulator|Testing and Inspection|Page 4875 > < All Technical Service Bulletins for Alternator Pulley:|89018