Brake Fluid Accumulator: Service and Repair
Accumulator Disposal

Warning:

-

The accumulator contains high pressure nitrogen gas. Do not puncture, expose to the flame, or attempt to disassemble the accumulator or
it may explode and severe personal injury may result
.

Accumulator Disposal

1. Secure the pump assembly in a vise and remove the accumulator by turning it counterclockwise with a open-end wrench.

2. Secure the accumulator in a vise so that the relief plug points straight up.

3. Slowly turn the plug 3-1/2 turns and then wait three minutes for all pressure to escape.

4. Remove the plug completely and dispose of the accumulator.