MDX V6-3.7L (2007)
Air Door Actuator / Motor: Service and Repair
Recirculation Control Motor Replacement
Recirculation Control Motor Replacement
1. Remove the glove box.
2. Disconnect the 7P connector (A) from the recirculation control motor (B). Remove the self-tapping screws and the recirculation control motor
from the heater unit.
3. Install the motor in the reverse order of removal. Make sure the pin on the motor is properly engaged with the linkage. After installation, make
sure the motor runs smoothly.