acura Workshop Repair Guides

Acura (Honda) Workshop Service and Repair Manuals

Sunlight Sensor Test|Page 739 > < Solar Sensor, HVAC|Locations
Page 1
background image

Solar Sensor: Testing and Inspection
Sunlight Sensor Test

Sunlight Sensor-Test

Measure the voltage between the terminals with the sensor out of direct sunlight.

^  With the connector connected (probe the back of it): 1.4 ± 0.2 V 
^  With the connector disconnected: 0.1 - 0.2 V

Sunlight Sensor Test|Page 739 > < Solar Sensor, HVAC|Locations