NSX V6-3.2L DOHC (VTEC) (1997)
from the same solenoid to the battery negative (-) terminal with a jumper lead as shown.
6. Press the auxiliary window switch to run the pump. After the pump has run for about five seconds, press and release the remote starter switch three
or four times to open and close the solenoid. Continue running the pump for about 30 seconds, then release the auxiliary window switch and open
and close the solenoid another three or four times.
7. Repeat steps 4-6 for the other three solenoids.
8. Reconnect the solenoids and the pump relay.
9. Connect the Anti-lock Brake (ALB) Checker and turn the Mode Selector to "1". Start the engine and release the parking brake. Push the Start Test
button on the ALB Checker.
10. While the pump is running, place your finger over the top of the solenoid return tube in the modulator reservoir and check for leaks.
If a solenoid is still leaking, replace the modulator/solenoid unit.