Condenser Fan Motor: Testing and Inspection
Condenser Fan Circuit

Condenser Fan Circuit Troubleshooting

1. Check the No.1 (30 A) fuse in the under-hood fuse/relay box, and the No.14 (10 A) fuse in the under-dash fuse/relay box.

Are the fuses OK?

YES - Go to step 2.

NO - Replace the fuse(s), and recheck.

2. Remove the condenser fan relay from the under-hood fuse/relay box, and test it.

Is the relay OK?

YES - Go to step 3.

NO - Replace the condenser fan relay.

3. Measure the voltage between the No.2 terminal of the condenser fan relay 4P socket and body ground.

Is there battery voltage?

YES - Go to step 4.

NO - Replace the under-hood fuse/relay box.

4. Connect the No.1 and No.2 terminals of the condenser fan relay 4P socket with a jumper wire.

Does the condenser fan run?

YES - Go to step 5.

NO - Go to step 8.

5. Disconnect the jumper wire.
6. Turn the ignition switch ON (II).

Condenser Fan Circuit|Page 9392 > < Power Relay Test|Page 9389