RSX L4-2.0L (VTEC) (2002)
Condenser Fan Motor: Testing and Inspection
Condenser Fan Circuit
Condenser Fan Circuit Troubleshooting
1. Check the No.1 (30 A) fuse in the under-hood fuse/relay box, and the No.14 (10 A) fuse in the under-dash fuse/relay box.
Are the fuses OK?
YES - Go to step 2.
NO - Replace the fuse(s), and recheck.
2. Remove the condenser fan relay from the under-hood fuse/relay box, and test it.
Is the relay OK?
YES - Go to step 3.
NO - Replace the condenser fan relay.
3. Measure the voltage between the No.2 terminal of the condenser fan relay 4P socket and body ground.
Is there battery voltage?
YES - Go to step 4.
NO - Replace the under-hood fuse/relay box.
4. Connect the No.1 and No.2 terminals of the condenser fan relay 4P socket with a jumper wire.
Does the condenser fan run?
YES - Go to step 5.
NO - Go to step 8.
5. Disconnect the jumper wire.
6. Turn the ignition switch ON (II).