acura Workshop Repair Guides

Acura (Honda) Workshop Service and Repair Manuals

Condenser Fan Circuit|Page 9393 > < Condenser Fan Circuit
Page 2
background image

7. Measure the voltage between the No.3 terminal of the condenser fan relay 4P socket and body ground.

Is there battery voltage?

YES - Replace the under-hood fuse/relay box.

NO - Repair open in the wire between the No.14 fuse in the under-dash fuse/relay box and the condenser fan relay.

8. Disconnect the jumper wire.

9. Disconnect the condenser fan 2P connector.

10. Check for continuity between the No.1 terminal of the condenser fan relay 4P socket and the No.2 terminal of the condenser fan 2P connector.

Is there continuity?

YES - Go to step 11.

NO - Repair open in the wire between the condenser fan relay and the condenser fan.

11. Check for continuity between the No.1 terminal of the condenser fan 2P connector and body ground.

Is there continuity?

YES - Replace the condenser fan motor.

NO - Check for an open in the wire between the condenser fan and body ground. If the wire is OK, check for poor ground at G302.