acura Workshop Repair Guides

Acura (Honda) Workshop Service and Repair Manuals

Condenser Fan Motor Relay, HVAC > < Condenser Fan Circuit|Page 9392
Page 1
background image

Condenser Fan Motor: Testing and Inspection
Radiator and Condenser Fans Common Circuit

Radiator and Condenser Fans Common Circuit Troubleshooting

1. Check the No.1 (30 A) and No.4 (20 A) fuses in the under-hood fuse/relay box, and the No.14 (10 A) fuse in the under-dash fuse/relay box.

Are the fuses OK?

YES - Go to step 2.

NO - Replace the fuse(s), and recheck.

2. Remove the condenser fan relay from the under-hood fuse/relay box.
3. Turn the ignition switch ON (II).

4. Measure the voltage between the No.3 terminal of the condenser fan relay 4P socket and body ground.

Is there battery voltage?

YES - Go to step 5.

NO - Repair open in the wire between the No.14 fuse in the under-dash fuse/relay box and the radiator fan relay, and the condenser fan relay.

5. Turn the ignition switch OFF.
6. Reinstall the condenser fan relay.
7. Make sure the A/C switch is OFF.
8. Turn the ignition switch ON (II).

9. Measure the voltage between the No.6 terminal of ECM/PCM connector B (24P) and body ground with the ECM/PCM connectors connected.

Is there battery voltage?

YES - Update the ECM/PCM if it does not have the latest software, or substitute a known-good ECM/ PCM, then recheck. If the
symptom/indication goes away with a known-good ECM/PCM, replace the original ECM/PCM.

NO - Repair open in the wire between the radiator fan relay, the condenser fan relay and the ECM/PCM.

Condenser Fan Motor Relay, HVAC > < Condenser Fan Circuit|Page 9392